Material Estimator

FIND A DISTRIBUTOR
NEAR YOU »

Homepage » Material Estimator

Select your product to see the technical data on the surface,
the drying time and thickness of application.

WACT (HI PERFORMANCE ACRYLIC COATING SYSTEM)
INTERIOR
YES
EXTERIOR
YES
SUPERFICIE COVERAGE
 
Pi2 / Gal. 
N.D.
M.2 / Gal. 
N.D.
Recommended thickness:
 
MINIMUM
N.D.
MAXIMUM
N.D.
PERCENTAGE OF SOLID
N.D.
DRYING TIME
 
Recoat window
N.D.
Pedestrian traffic
N.D.
Normal traffic
N.D.
Heavy equipment traffic
N.D.
Thinner
N.D.
DILUTION
N.D.
Mixing ratio
 
A
N.D.
B
N.D.
ACIA CERTIFIED
N.D.
QUANTITÉ DE COV
N.D.
LEED COMPLIANT
N.D.
SUPERFICIE
 
Pi2 / Lt.
N.D.
M. 2 / Lt.
N.D.
SACT
INTERIOR
x
EXTERIOR
x
SUPERFICIE
 
Pi2 / Gal. 
N.D.
M. 2 / Gal. 
N.D.
Recommended thickness:
 
MINIMUM
N.D.
MAXIMUM
N.D.
Solid %
N.D.
DRYING TIME
 
Recoat window
N.D.
Pedestrian traffic
N.D.
Normal traffic
N.D.
Heavy equipment traffic
N.D.
Thinner
N.D.
DILUTION
N.D.
Mixing ratio
 
A
N.D.
B
N.D.
ACIA CERTIFIED
N.D.
QUANTITÉ DE COV
N.D.
LEED COMPLIANT
N.D.
SUPERFICIE
 
Pi2 / Lt.
N.D.
M. 2 / Lt.
N.D.
ECTR
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils  
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs  
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
YES
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
ECTROP
INTERIOR
Yes
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
YES
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
LECTR
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
YES
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
ECTCR
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
YES
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
LECTCR
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
YES
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
ECTCF
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
YES
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
WECTR
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
YES
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
WUCTR
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
YES
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
ECTM
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
YES
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
PACT
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
NO
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
SPACT
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001 
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
NO
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.
18,5/ 8mils 
SPACT
INTERIOR
x
EXTERIOR
 
SUPERFICIE
 
Pi2 / Gal. 
200/ 8mils 
M. 2 / Gal. 
18,5/ 8mils 
Recommended thickness:
 
MINIMUM
8 mils 
MAXIMUM
12 mils 
PERCENTAGE OF SOLID
100%
DRYING TIME
 
Recoat window
8-12 hrs
Pedestrian traffic
12 - 24hrs 
Normal traffic
24 - 48hrs 
Heavy equipment traffic
> 48hrs 
Thinner
Sct-0001 
DILUTION
Sct-0001
Mixing ratio
 
A
2
B
1
ACIA CERTIFIED
YES
COV QUANTITY
0
LEED COMPLIANT
YES
SUPERFICIE
 
Pi2 / Lt.
200/ 8mils 
M. 2 / Lt.